Products / Safety & Monitoring Preservation Movement Storage Lifts
Category 01 / 20 items

Safety & Monitoring.

A sensing and protection layer engineered around the failure modes of dormant vehicles. Each device reports to the PVS platform — one screen, every vehicle.

Items20 SKUs IntegrationPVS Platform CoveragePer-vehicle & facility
What we monitor

Three failure modes. Twenty sensors.

Every product in this category exists to catch one of three failure modes before it costs a vehicle, a bay, or a building.

01

Electrical

Battery drain, parasitic loads, voltage drift, charger failure — anything that prevents a vehicle from starting on first turn.

02

Thermal & Fire

Ambient temperature, HVAC failure, heat rate-of-rise, smoke, and flame — the events that can take a whole facility down.

03

Movement & Access

Door state, bay-level occupancy, key location, tamper detection — the audit trail that protects the asset and the operator.

Full catalog · 20 items

The Safety & Monitoring product line.

Every product is designed to work standalone or as part of the integrated PVS platform.

SF · 01

Voltage Monitor

Wireless12V / 24V

Continuous battery voltage tracking with configurable alert thresholds. Catches every form of parasitic drain — from interior lights to legacy GPS — before a vehicle drops below a safe-start threshold.

Resolution0.01 V
Battery life2 years
Range120 m mesh
SF · 02

Heat & Temperature Monitor

LoggingAlerting

Tracks ambient and engine-bay temperature. Catches thermal runaway and HVAC failure long before damage starts. Logs every reading to the platform for trend analysis.

Range−40 to 125°C
Accuracy±0.5°C
SF · 03

Voltage & Temperature Monitor

Combo

Combined unit — single device, both feeds. Half the sensors per bay, same coverage. Recommended for new installations.

Feeds2
Form factorCompact
SF · 04

Flame Detector

OpticalCode-rated

Optical flame sensing tuned for vehicle storage environments. Faster than smoke detection for fast-developing fires — critical for facilities with EVs and high-octane fuels.

Response< 3 sec
Field of view90°
SF · 05

Heat & Temp Monitor + Shunt

EV-readyAuto-cut

Adds an automatic battery disconnect to thermal protection. When the unit detects thermal anomaly, it isolates the battery before the event escalates. Critical for stored EVs and hybrids.

Cut response< 1 sec
Max current300 A
SF · 06

Smoke Detector

Photoelectric

Photoelectric detector calibrated for facility air quality — fewer false alarms from dust, exhaust, and ambient particulates than commodity detectors.

SF · 07

Heat & Smoke Detector

Dual-sensing

Dual-sensing unit. Heat rate-of-rise plus optical smoke in a single low-profile housing. The right default detector for most PVS facilities.

SF · 08

Receiver / Home Base

HubPoE

The facility hub. Aggregates every PVS sensor and relays to the management platform. Up to 2,000 endpoints per receiver, with mesh radio plus ethernet uplink and battery failover.

SF · 09

Signal Repeater

Mesh

Extends the sensor mesh across large or multi-floor facilities. Pole, ceiling, or wall mount. No dead spots, no manual relay configuration.

SF · 10

Door Sensor

Audit

Bay-level open/close tracking. Builds an audit trail of every access event tied to the vehicle inside, with timestamps and badge correlation for facilities with key control systems.

SF · 11

Key Location Tracker

Operations

Always know which key is where. Cuts intake and release time in busy facilities and eliminates the "lost key" emergency. Tag every key, locate from the platform.

SF · 12

Vehicle Location Tracker

Bay-level

Bay-accurate vehicle location with tamper alerting. Built for facilities with hundreds of stalls where finding the right car becomes its own operational cost.

SF · 13

Smart Charger Power Solutions

Infrastructure

Charging infrastructure scoped to facility load — sized for any mix of collector, fleet, and EV vehicles. PVS handles the engineering, electrical design, and installation.

SF · 14

Smart Charger Maintainers

Per-vehicle

Per-vehicle intelligent maintainers. Chemistry-aware multi-stage charging — long-cycle health, not just trickle charging. No manual cycling.

SF · 15

Battery Cut Off

Long-term

Physical disconnect that eliminates parasitic drain on the deepest dormancy intervals. The right product when a vehicle is sleeping for a year or more.

SF · 16

Battery Cut Off + Sensors

Smart cutoff

Disconnect with onboard voltage and temperature reporting. Cut and watch — the platform still sees the battery state even while it's electrically isolated.

SF · 17

Memory Saver System

ECU-safe

Battery cutoff with integrated maintainer. Preserves ECU memory and radio presets through dormancy — no relearn cycles, no error codes at startup.

SF · 18

Axle Temperature Monitor

Fleet · RV · Trailer

For fleet, RV, and trailer use. Catches wheel bearing failures before they strand a vehicle on the road or take a trailer out of service.

SF · 19

Tire Monitoring System

TPMS

Per-tire pressure and temperature. Critical for long-dormancy storage where slow leaks and flat-spotting are the most common avoidable damage.

SF · 20

Camera Systems

Owner view

Facility and bay-level cameras integrated with the PVS platform. Owner-visible feeds optional — owners can check on their vehicle from the Vehicle Vitals app.

Other categories

Continue browsing the catalog.

Three more categories cover the rest of the product platform.

Specifying for your facility?

Talk to a PVS specialist.